PCE-ET 5000

Earth Tester

The grounding meter is a versatile ohmmeter.

With this grounding meter a variety of resistance measurements can be performed. Thus, with the grounding meter, the possibility exists to perform a normal resistance measurement of 2- or 4-pole application. It is also possible to determine the resistance of the soil with the grounding meter. For the measurement of earth resistance corresponding earth spikes are included in the scope of supply. These ground spikes can easily be connected to the grounding device via the supplied separate 20 meter / 66 ft cable.

 

Mobile use thanks to battery and batteries
 Data memory for later analysis on the PC
Visual connection aid for easy operation
Alarm in case of incorrect connection of the measuring line
Direct and indirect resistance measurement
Interference currents, interference voltages, frequencies

SPECIFICATION

​

Data storage                                                                 100 readings

Operating conditions                                                       0 ... 40°C / 32 ... 104°F, < 80% RH (non-condensing)

Charge ambient conditions to the battery                            10 ... 40°C / 50 ... 104°F, < 80% rh (non-condensing)   

Storage conditions                                                         -10 ... 50°C / 50 ... 122°F, < 90% rh (non-condensing)

Storage conditions for the battery                                      -20 ... 30°C / -4 ... 86°F, < 80% rh (non-condensing)

Storage height                                                               < 12,000 m / 39,370 ft

Operating altitude                                                          < 2,000 m / 6,561 ft

Clamp diameter                                                             51 mm

Display                                                                         Backlit LCD, 9,999 digits

Display measuring range exceeded                                   > LIMIT

Display below measuring range                                        -

Measuring frequency earthing resistance / leakage current    1 Hz (If the average value function is activated: one value every four seconds)

Measuring frequency voltage measurement                         2 Hz

Measuring frequency interference voltage                           4 Hz

Measuring frequency interference frequency                        1 Hz                          

Measuring frequency interference current                            1 Hz

interfaces                                                                      Measuring connection: E, ES, S, H, pliers
                                                                                  connection USB-B, charging connection                                                                   

Power supply batteries                                                    6 x 1.5V D LR14 batteries

Power supply battery                                                      1 x 7.2V nickel-metal hydride battery pack                                                                                            

Power supply power supply                                                     Primary: 100 ... 240V, 50 ... 60 Hz

                                                                                         Secondary: 12V, 3A

Max. Power consumption with power supply                              15V A

Max. Power consumption with battery or rechargeable battery       6V A

Running time in battery mode                                                   About 5 hours

Running time in the battery                                                      About 9 hours (without backlight)

Maximum input voltage

Maximum input voltage relative to earth                                    300V rms (CAT III)

Insulation thickness                                                                6880V AC: 15 seconds

Overvoltage protection                                                          250V AC between the connections

Dimensions                                                                          260 x 125 x 280 mm / 10.2 x 4.9 x 11 in

Weight                                                                               About 2.5 kg / 5.5 lbs                                                                        

Standardize                                                                         Safety: EN61010-1: 2001, EN61010-031: 2002

                                                                                         Pollution degree 2, CAT III 300V,

                                                                                         EMC: EN61000-3-2: 2000, IEC61326-1: 1997 A

 

 